IAI America E-Con User Manual
Page 47
39
3. XSEL-R/S/RX/SX/RXD/SXD
[1] Network Setting Check
Confirm that the 2nd digit of I/O Parameter No.225 Network I/F Module Control setting is showing “2”
(DeviceNet).
No.
Parameter name
Default
Input Range
Unit
Remarks
225
Network I/F Module
Control
2*
0*H to 3*H
─
bits 4-7 (2nd digit):
Network I/F Module 2 types
0:Not Mounted
1:CC-Link
2:DeviceNet
3:PROFIBUS
[2] I/O Port Assignment Classification Setting
I/O Parameter No.1
Set I/O Port Assignment Classification
No.
Parameter name
Default
Input Range
Unit
Remarks
1
I/O Port Assignment
Classification Setting
(Note)
1
0 to 1
─
0: Fixed Allocation
1: Automatic Allocation
• Reference Priority of I/O Port Assignment
when automatically assigned
Port Number
(No.0 to 299/No.300 to 599)
1) Network I/F Module1
2) I/O slot 1 (I/O1) Mounting board
3) I/O slot 2 (I/O2) Mounting board
* I/O slot 1 (I/O1) Assigned for the
continuously mounted range from
mounting board
• Reference Priority of extension I/O ports
at automatic assignment
Port Number
(No.1000 to 3999/No.4000 to 6999)
1) Network I/F Module 2
2) Expansion I/O unit
3) IA Net
Note If the automatic assignment is selected, the input port is assigned to an extension input port area
(No.1000 to 3999). The output port is assigned to an extension output port area (No.4000 to 6999).
If the fixed assignment is selected, the user will manually assign the input standard input port area
(No.0 to 299) or extension input port area (No.1000 to 3999). For the output port, the user will
manually assign the output standard output port area (No.300 to 599) or the extension output port
area (No.4000 to 6999).