Page 47

background image

39

3. XSEL-R/S/RX/SX/RXD/SXD

[1] Network Setting Check

Confirm that the 2nd digit of I/O Parameter No.225 Network I/F Module Control setting is showing “2”
(DeviceNet).

No.

Parameter name

Default

Input Range

Unit

Remarks

225

Network I/F Module
Control

2*

0*H to 3*H

bits 4-7 (2nd digit):
Network I/F Module 2 types

0:Not Mounted
1:CC-Link
2:DeviceNet
3:PROFIBUS

[2] I/O Port Assignment Classification Setting

I/O Parameter No.1

Set I/O Port Assignment Classification

No.

Parameter name

Default

Input Range

Unit

Remarks

1

I/O Port Assignment
Classification Setting

(Note)

1

0 to 1

0: Fixed Allocation
1: Automatic Allocation

• Reference Priority of I/O Port Assignment

when automatically assigned

Port Number

(No.0 to 299/No.300 to 599)

1) Network I/F Module1
2) I/O slot 1 (I/O1) Mounting board
3) I/O slot 2 (I/O2) Mounting board
* I/O slot 1 (I/O1) Assigned for the

continuously mounted range from
mounting board

• Reference Priority of extension I/O ports

at automatic assignment

Port Number

(No.1000 to 3999/No.4000 to 6999)

1) Network I/F Module 2
2) Expansion I/O unit
3) IA Net

Note If the automatic assignment is selected, the input port is assigned to an extension input port area

(No.1000 to 3999). The output port is assigned to an extension output port area (No.4000 to 6999).
If the fixed assignment is selected, the user will manually assign the input standard input port area
(No.0 to 299) or extension input port area (No.1000 to 3999). For the output port, the user will
manually assign the output standard output port area (No.300 to 599) or the extension output port
area (No.4000 to 6999).