42
3. XSEL-R/S/RX/SX/RXD/SXD
3.5 Setting
example
(1) Example for when using only DeviceNet
It is how to establish the setting when using DeviceNet to 16 points of each input and output from the top
of the standard I/O ports, and no other I/O port (for I/O board, etc.) is to be used.
Standard Input Port No.0 to 15
Standard Output Port No.300 to 315
(DeviceNet board)
Not Applicable (I/O board)
• I/O Parameters
No.
Parameter name
Default
(Reference)
Input Range
Unit
Remarks
1
I/O Port Allocation Type
1
0 to 1
0
0:Fixed Allocation
1:Automatic Allocation
•Reference 1 Priority of I/O Port Assignment
when automatically assigned
Port Number
(No.0 to 299/No.300 to 599)
1) Network I/F Module 1
2) I/O slot 1 (I/O1) Mounting board
3) I/O slot 2 (I/O2) Mounting board
* I/O slot 1 (I/O1) Assigned for the
continuously mounted range from
mounting board
•Reference 2 Priority of extension I/O ports at
automatic assignment
Port Number
(No.1000 to 3999/No.4000 to 6999)
1) Network I/F Module 2
2) Expansion I/O unit
3) IA Net
2
Standard I/O Fix-Allocated
Input Port Start No.
0
-1 to 599
-1
0+ (Multiples of 8)
[Ineffective when -1 is selected]
3
Standard I/O Fix-Allocated
Output Port Start No.
300
-1 to 599
-1
300+ (Multiples of 8)
[Ineffective when -1 is selected]