beautypg.com

5 setting example – IAI America E-Con User Manual

Page 50

background image

42

3. XSEL-R/S/RX/SX/RXD/SXD

3.5 Setting

example

(1) Example for when using only DeviceNet

It is how to establish the setting when using DeviceNet to 16 points of each input and output from the top
of the standard I/O ports, and no other I/O port (for I/O board, etc.) is to be used.

Standard Input Port No.0 to 15
Standard Output Port No.300 to 315
(DeviceNet board)

Not Applicable (I/O board)

• I/O Parameters

No.

Parameter name

Default

(Reference)

Input Range

Unit

Remarks

1

I/O Port Allocation Type

1

0 to 1

0

0:Fixed Allocation
1:Automatic Allocation
•Reference 1 Priority of I/O Port Assignment

when automatically assigned

Port Number

(No.0 to 299/No.300 to 599)

1) Network I/F Module 1
2) I/O slot 1 (I/O1) Mounting board
3) I/O slot 2 (I/O2) Mounting board
* I/O slot 1 (I/O1) Assigned for the

continuously mounted range from
mounting board

•Reference 2 Priority of extension I/O ports at

automatic assignment

Port Number

(No.1000 to 3999/No.4000 to 6999)

1) Network I/F Module 2
2) Expansion I/O unit
3) IA Net

2

Standard I/O Fix-Allocated
Input Port Start No.

0

-1 to 599

-1

0+ (Multiples of 8)
[Ineffective when -1 is selected]

3

Standard I/O Fix-Allocated
Output Port Start No.

300

-1 to 599

-1

300+ (Multiples of 8)
[Ineffective when -1 is selected]