Page 77: Mma-570 direct/indirect charge - maintenance

background image

3. Excessive turbine speed

4. Excessive robot speed

5. Excessive inner/outer shaping air

6. Excessive target distance

1. Turbine drive air not present

2. Bearing air return signal not

present

3. Brake air is activated

3. For optimum transfer efficiency and

spray pattern control, the bell rotational

speed should be set at the minimum

required to achieve proper atomization of

the coating material.
4. For optimum transfer efficiency, spray

pattern control, bell speed, and robot

speed should be set at the minimum

to achieve desired results of part to be

coated.
5. Shaping air should be set at the min-

imum volume required to gently direct

the spray pattern toward the part being

coated. Excessive shaping air will cause

some atomized particles to “blow-by” the

part or bounce back onto the atomizer.

6. The recommended target distance

is between 6 and 12-inches (152.4-

304.8mm) (see “Target Distance” in the

“Operation” section of this manual).

1. Verify supply air pressure.

2. a. Verify bearing air return signal.
b. Increase bearing air supply pressure

to 90 psig (±10 psig) (620.5 +/- 69 kPa).

3. Remove brake air signal (turbine air

and brake air must be interlocked to

prevent both from being used simultane-

ously).

General Problem

Possible Cause

Solution

TROUBLESHOOTING GUIDE - INDIRECT CHARGE

(Cont.)

Low Transfer

Efficiency (or light

coverage) (Cont.)

No Turbine Air

Damaged fiber optic cable be-

tween robot plate and control

panel

Connection at robot or bell plate

is loose

Fiber optic transmitter failure

Bad transceiver module

Excessive vibration

a. Repair or replace fiber optic cable.

b. Bad splice connection or too many splic-

es. Maximum three (3) splices permitted.

Re-install cable and tighten locking set screw.

Replace fiber optic transmitter.

Replace transceiver module.

a. Check bell cup for damage

b. Check bell cup for excessive paint

buildup

c. Insure bell cup is tightened properly

d. Check cup and shaft tapers for cleanliness

Speed Feedback

Fault

MMA-570 Direct/Indirect Charge - Maintenance

Ransburg

LN-9279-13