Preventive maintenance schedule, Ransburg, Mma-570 preventive maintenance schedule – Ransburg MMA-570 Direct_Ind Charge Atomizer A13366 User Manual

Page 56: Mma-570 direct/indirect charge - maintenance

background image

MMA-570 PREVENTIVE MAINTENANCE SCHEDULE

Procedure

Yearly

6 Months

3 Months

Monthly

2 Weeks

Weekly

End of Shift

Mid-Shift

Mid Shift Cleaning

• Wipe electrodes

• Wipe shroud

• Visually inspect cup

End of Shift Cleaning

• Wipe electrodes

• Wipe shroud

• Wipe bell cup down

• Change cloth cover

Shaping Air Shroud

• Clean inner shape air ring

• Clean outer shape air ring

• Remove and clean

Bell cup removal/inspection/

cleaning

Fluid tip inspection/cleaning

Inspect Valve and Seat

Assembly in valve module

for leaking

Replace Valves and Seats

in valve module

High Voltage Cable

Inspections

High Voltage Testing

Regreasing of High Voltage

Cables
Check resistance of High

Voltage Electrodes

Regreasing Electrode

Cavities of High Voltage

Ring and High Voltage Input
Inspect all screws

• Replace if broken

• Inspect for wear

• Tighten per specifications

Inspection of Electrode
Replace Electrodes

Inspection of Tubing Bundle
Regrease Tubing Bundle
Replace Tubing Bundle
Replace High Voltage Cable
Inspect Turbine Spindle

taper and threads

Frequency (Maximum)

• •

• •

• •

• •

MMA-570 Direct/Indirect Charge - Maintenance

Ransburg

LN-9279-13

53