Fluid Tube Removal
Tubing Removal (Mounting End)
Using the tubing removal tool (A11373-00) select
the appropriate size end for the tube you want
to remove, 8mm or 6mm. Place the opening
around the tube and press down on the quick
release collet. Using your other hand, pull the
tubing from the collet. Remove all tubing from
the collets and also remove the fluid lines held
on with compression nuts.
Weep Port Locations
Inspect weep ports for contamination or other visi-
ble leakage around valves. Follow instructions as
follows for damage to valves, seats, or performing
preventative maintenance.
Using the valve removal tool (A11922-00), engage
the four (4) pins on the tool to the corresponding four
(4) hole pattern in the top of the valve. Using a 1/2”
(13mm) socket, end wrench, or adjustable wrench,
remove the valve by turning counter-clockwise.
Valve Removal
Using the seat removal tool (A10756-00), insert
the smaller hex end into the block to engage the
seat female hex. Using a 3/8” (10mm) socket
end-wrench, or adjustable wrench, remove the
seat by turning counter-clockwise.
Valve and Seat Removal / Installation
(Mounting Manifold Assembly)
MMA-570 Direct/Indirect Charge - Maintenance
Ransburg
LN-9279-13
65