Fluid Tube Removal

Tubing Removal (Mounting End)

Using the tubing removal tool (A11373-00) select

the appropriate size end for the tube you want

to remove, 8mm or 6mm. Place the opening

around the tube and press down on the quick

release collet. Using your other hand, pull the

tubing from the collet. Remove all tubing from

the collets and also remove the fluid lines held

on with compression nuts.

Weep Port Locations

Inspect weep ports for contamination or other visi-

ble leakage around valves. Follow instructions as

follows for damage to valves, seats, or performing

preventative maintenance.

Using the valve removal tool (A11922-00), engage

the four (4) pins on the tool to the corresponding four

(4) hole pattern in the top of the valve. Using a 1/2”

(13mm) socket, end wrench, or adjustable wrench,

remove the valve by turning counter-clockwise.

Valve Removal

Using the seat removal tool (A10756-00), insert

the smaller hex end into the block to engage the

seat female hex. Using a 3/8” (10mm) socket

end-wrench, or adjustable wrench, remove the

seat by turning counter-clockwise.

Valve and Seat Removal / Installation

(Mounting Manifold Assembly)