4 ouput signals – FEC AFC1500 User Manual
Page 92
![background image](/manuals/346001/92/background.png)
AFC1500 Multi-2 Unit Hardware Manual (Rev2.1)
PAGE 5 - 48
Chapter 5: Control Interfaces
5.9.4 Ouput Signals
The Multi-2 Unit is capable of providing over 570 Output signals to indicate the status of the Multi-2
Unit and of all the AFC1500 SAN Controllers connected to it (up to 31 controllers).
See Section 4.7.3 for available output signals.
Address
Signal
FEC Multi-2
Bank
Bit
RX(n+0)0
Total Reject
1
1
RX(n+0)1
Total Accept
1
2
RX(n+0)2
Abnormal
1
3
RX(n+0)3
Ready
1
4
RX(n+0)4
Busy
1
5
RX(n+0)5
End
1
6
RX(n+0)6
Sequence Output 0
1
7
RX(n+0)7
Sequence Output 1
1
8
RX(n+0)8
Sequence Output 2
1
9
RX(n+0)9
Sequence Output 3
1
10
RX(n+0)A
Spindle in Bypass
1
11
RX(n+0)B
Current Warning
1
12
RX(n+0)C
Spindle No.1 Accept
1
13
RX(n+0)D
Spindle No.1 Reject
1
14
RX(n+0)E
Spindle No.1 ABN.
1
15
RX(n+0)F
Spindle No.1 BYP
1
16
RX(n+1)0
Spindle No.2 Accept
1
17
RX(n+1)1
Spindle No.2 Reject
1
18
RX(n+1)2
Spindle No.2 ABN
1
19
RX(n+1)3
Spindle No.2 BYP
1
20
RX(n+1)4
Spindle No.3 Accept
1
21
RX(n+1)5
Spindle No.3 Reject
1
22
RX(n+1)6
Spindle No.3 ABN
1
23
RX(n+1)7
Spindle No.3 BYP
1
24
RX(n+1)8
Spindle No.4 Accept
1
25
RX(n+1)9
Spindle No.4 Reject
1
26
RX(n+1)A
Spindle No.4 ABN.
1
27
RX(n+1)B
Spindle No.4 BYP
1
28
RX(n+1)C
Spindle No.5 Accept
1
29
RX(n+1)D
Spindle No.5 Reject
1
30
RX(n+1)E
Spindle No.5 ABN.
1
31
RX(n+1)F
Spindle No.5 BYP
1
32
RX(n+2)0
Spindle No.6 Accept
2
1
RX(n+2)1
Spindle No.6 Reject
2
2
RX(n+2)2
Spindle No.6 ABN
2
3
RX(n+2)3
Spindle No.6 BYP
2
4
RX(n+2)4
Spindle No.7 Accept
2
5
RX(n+2)5
Spindle No.7 Reject
2
6
RX(n+2)6
Spindle No.7 ABN
2
7
RX(n+2)7
Spindle No.7 BYP
2
8
RX(n+2)8
Spindle No.8 Accept
2
9
RX(n+2)9
Spindle No.8 Reject
2
10
RX(n+2)A
Spindle No.8 ABN.
2
11
RX(n+2)B
Spindle No.8 BYP
2
12
RX(n+2)C
Spindle No.9 Accept
2
13
RX(n+2)D
Spindle No.9 Reject
2
14
RX(n+2)E
Spindle No.9 ABN.
2
15
RX(n+2)F
Spindle No.9 BYP
2
16
:
Bit
Signal
Description
For
CC-Link
Comm.
Only
RX(n+x)0
Unusable
The last 16 bits are reserved for CC-Link
Communication only
regardless of how many
stations are set.
…
…
RX(n+x)F
Unusable
These Output signals are user
configurable using the AFC User
Console Software and may be
programmed on any designated
bit.
The Output signal mapping
shown is only an EXAMPLE.
The signals may be programmed
for
placement
in
ANY
bit
position.