4 ouput signals (ch1 ~ ch16) – FEC AFC1500 User Manual
Page 103
AFC1500 Multi-2 Unit Hardware Manual (Rev2.1)
PAGE 5 - 59
Chapter 5: Control Interfaces
5.11.4 Ouput Signals (CH1 ~ CH16)
The Multi-2 Unit is capable of providing over 570 Output signals to indicate the status of the Multi-2
Unit and of all the AFC1500 SAN Controllers connected to it (up to 31 controllers).
See Section 4.7.3 for available output signals.
CH. No.
Bit
Signal
FEC Multi-2
Bank
Bit
Output CH.
No.01
0bit
Total Reject
1
1
1bit
Total Accept
1
2
2bit
Abnormal
1
3
3bit
Ready
1
4
4bit
Busy
1
5
5bit
End
1
6
6bit
Sequence Output 0
1
7
7bit
Sequence Output 1
1
8
8bit
Sequence Output 2
1
9
9bit
Sequence Output 3
1
10
10bit Spindle in Bypass
1
11
11bit
Current Warning
1
12
12bit
Spindle No.1 Accept
1
13
13bit
Spindle No.1 Reject
1
14
14bit
Spindle No.1 ABN.
1
15
15bit
Spindle No.1 BYP
1
16
Output CH.
No.02
0bit
Spindle No.2 Accept
1
17
1bit
Spindle No.2 Reject
1
18
2bit
Spindle No.2 ABN
1
19
3bit
Spindle No.2 BYP
1
20
4bit
Spindle No.3 Accept
1
21
5bit
Spindle No.3 Reject
1
22
6bit
Spindle No.3 ABN
1
23
7bit
Spindle No.3 BYP
1
24
8bit
Spindle No.4 Accept
1
25
9bit
Spindle No.4 Reject
1
26
10bit
Spindle No.4 ABN.
1
27
11bit
Spindle No.4 BYP
1
28
12bit
Spindle No.5 Accept
1
29
13bit
Spindle No.5 Reject
1
30
14bit
Spindle No.5 ABN.
1
31
15bit
Spindle No.5 BYP
1
32
Output CH.
No.03
0bit
Spindle No.6 Accept
2
1
1bit
Spindle No.6 Reject
2
2
2bit
Spindle No.6 ABN
2
3
3bit
Spindle No.6 BYP
2
4
4bit
Spindle No.7 Accept
2
5
5bit
Spindle No.7 Reject
2
6
6bit
Spindle No.7 ABN
2
7
7bit
Spindle No.7 BYP
2
8
8bit
Spindle No.8 Accept
2
9
9bit
Spindle No.8 Reject
2
10
10bit
Spindle No.8 ABN.
2
11
11bit
Spindle No.8 BYP
2
12
12bit
Spindle No.9 Accept
2
13
13bit
Spindle No.9 Reject
2
14
14bit
Spindle No.9 ABN.
2
15
15bit
Spindle No.9 BYP
2
16
:
CH. No.
Bit
Signal
Output CH.
No.16
0bit
8
1
…
15bit
8
32
The CH. No. at the Master input side differs according to node address settings.
Please check before operating the unit.
These Output signals are user
configurable using the AFC User
Console Software and may be
programmed on any designated
bit.
The Output signal mapping
shown is only an EXAMPLE.
The signals may be programmed
for
placement
in
ANY
bit
position.