AFC1500 Multi-2 Unit Hardware Manual (Rev2.1)
PAGE 5 - 24
Chapter 5: Control Interfaces
Profibus Specifications
Speed
9.6K - 12M baud - auto selected
Nodes
126 Note: Node 126 is reserved for commissioning purposes only
Distance
200m max. at 1.5Mbit/s extendable with repeaters.
Cable
Shielded Copper Twisted Pair or fiber optic
Communications Type
Master/Slave - EIA RS485
Protocol Version
Ver. 1.10
Maximum Cyclic I/O Size
244bytes In, 244 bytes out max. 416 total bytes max.
Data transmission
The module only supports cyclic I/O data transmission.
Configuration
FEC Profibus I/O configuration is programmable using the AFC User Console software. I/O can be
set as required by the application according to parameter limits set forth by the GSD (Profibus)
configuration file. The AFC Software allows configuration of the number of I/O in the Multi Unit.
Configuration of the Profibus Master MUST match the configuration of the FEC Profibus slave. In
the Profibus Master setup, input size and output size is set as “byte” ordering. (Do not use “word”
ordering. This will inverse the I/O location) When setting the Profibus Master configuration, PLC
input size refers to FEC output size (ie. Accept, Reject, Busy, etc.) and PLC output size refers to
FEC inputs (ie. Start, Stop, Reset, etc.). FEC will show up as 2 modules. Module 1 is inputs, module
2 is outputs. (See AnyBus-S Reference at the end of this chapter for I/O Setting example.)
GSD File
Each device on a Profibus network is associated with a GSD file containing all necessary
information about the device to be connected. The network configuration program uses this file
during configuration of the network.
The GSD file associated with the FEC device can be downloaded from the FEC website. www.fec-
usa.com (File : hms_1003.gsd)
Direct link:www.fec-usa.com/fecusacomnew/support/index.htm
(The file can also be downloaded directly from HMS - www.hms.se)