beautypg.com

FEC AFC1500 User Manual

Page 18

background image

AFC1500 Multi-2 Unit Hardware Manual (Rev. 2)

PAGE 1 - 4

Chapter 1: Outline

1.3 Safety Precautions

To ensure the most effective and extended use of all equipment, adhere to the following precautions:

Wiring

Use only the specified cables for all system connections.

Do not use a high voltage circuit as a frame ground (FG). Also, the frame ground should be

separate from the power ground. The use of a grounding rod located as close as possible to

the enclosure housing the AFC1500 Multi-2 Unit is preferable.

Circuit breakers or fuses are required on branch circuit power feeds to the Multi-2 Unit.

PLC I/O cables must be run separate from any high voltage sources or cabling, and must not

exceed 50 feet.

Installation Environment

The AFC1500 Multi-2 Unit should be placed in a NEMA 12 enclosure.

Using the equipment in the following locations may lead to malfunction or breakdown. Avoid

using in these areas or use an air conditioner.

Areas under direct sunlight or if the environmental temperature is out of the 32~122

 

¡

0~50

¢

) range.

Areas where relative humidity is out of the 20-90% range, the temperature change is

drastic or where the area is exposed to mist and water drops.

Do not use at the following locations. (Contact FEC Inc. if necessary for clarification)

Areas where conductive powder, oil, mist, salt or organic solvents exist.

Areas that have corrosive or combustible gases.

Areas that have strong electric or magnetic fields.

Areas where strong vibration or shock could be transmitted directly to a Multi 2 Unit.

Static Electricity

The AFC1500 Multi-2 Unit incorporates many electronic Surface Mounted Devices (SMD). It

is advisable to strictly adhere to practices for safe electrostatic discharge in order to prevent

damage to the system components when handling them.

Cleaning

Do not use any organic solvents, such as thinner, to clean a Multi-2 Unit. The solvent could

melt the surface paint, or penetrate inside and cause damage. A cloth dampened with alcohol

or warm water should be used to lightly wipe the components.

Electrical Noise Prevention

Multi-2 Units must be located a minimum of 600mm from high transient voltage sources such

as transformers, motor starters, AC inverters and AC contactors. If it cannot be avoided, the

unit must be shielded.

If high powered devices are used inside the enclosure, they must use a surge suppression

device.

Make sure that the power supply lines and cables for connecting the unit and tool are not run

together inside the same duct.

Handling and Shipping

It is critical that AFC1500 System components are properly handled and shipped in order to

maintain the system’s integrity. Adhere to the following requirements for shipping and

handling:

Loose AFC1500 Multi-2 Units must be individually packaged and shipped in anti-static

containers or wrap to prevent damage from electrostatic discharge.

If the Multi Unit is to be shipped in an enclosure, tighten all mounting screws to prevent

the unit from being dislodged.

Do not ship or store the unit in environments where the temperature is out of the

23~131

 

(-5~55

¢

) range or where the humidity is above 90%.