6 profibus, Interface – FEC AFC1500 User Manual
Page 67

AFC1500 Multi-2 Unit Hardware Manual (Rev2.1)
PAGE 5 - 23
Chapter 5: Control Interfaces
5.6 Profibus
®
Interface
The Profibus-DP communication interface allows slave connection to an industrial Profibus network.
Profibus-DP allows industrial devices to be controlled over an open network architecture enabling
device connection at various locations in the field. This “Fieldbus” technology reduces
hardwiring/cabling & provides ease of installation. It can interface to many devices such as limit
switches, sensors, directional valves, motor starters, bar code readers, process sensors, frequency
drives, etc. The network can have up to 126 nodes. Its maximum communication baud rate is 12M baud
and its minimum baud rate is 9.6K baud.
Node addressing is selectable using the address selection switches. Baud rate is auto detected from the
master and no user setup is required. Module & Network status LED’s provide network diagnostics.
Maximum I/O data is 244 input bytes & 244 output bytes. FEC Inputs match the discrete input layout.
FEC Output location is programmed using the AFC User Console Software.
Note: The Profibus interface is implemented according to the Profibus-DP EN 50 170 (DIN 19245 Part
1) specification.
FEC integrates the Profibus-DP board manufactured by HMS Fieldbus Systems AB into the Multi-Unit
modular I/O board. For further technical information on the Profibus interface go to the HMS website.
(www.hms.se)
Further Profibus information can be found on the Profibus website at www.profibus.com.
Item
Description
1
Application Connector
2
Profibus Connector
3
Terminator Switch
4
Address Switches
5
Status LEDs (4)
6
Watchdog LED
Red - (flashing @ 2Hz) - ASIC and FLASH ROM check fault.
Green (flashing @ 2Hz) - module not initialized.
Green (flashing @ 1Hz) - module initialized and running OK.
Red (flashing @ 1Hz) - RAM check fault.
Red (flashing @ 4Hz) - DPRAM check fault.
TERMINATION
2
1
4
5
6
3
- Represents switch position