5.7.4 Ouput Signals (Word 01 ~ Word 16)
The Multi-2 Unit is capable of providing over 570 Output signals to indicate the status of the Multi-2
Unit and of all the AFC1500 SAN Controllers connected to it (up to 31 controllers).
See Section 4.7.3 for available output signals.
Since Modbus Plus sends I/O signals 8 bits at a time, and trying to use the data as a word, all
bits and bytes are transferred backwards.
Word No.
Bit
Signal
FEC Multi-2
Bank
Bit
Output
Word
No.01
0bit
Sequence Output 1
1
8
1bit
Sequence Output 0
1
7
2bit
End
1
6
3bit
Busy
1
5
4bit
Ready
1
4
5bit
Abnormal
1
3
6bit
Total Accept
1
2
7bit
Total Reject
1
1
8bit
Spindle No.1 BYP
1
16
9bit
Spindle No.1 ABN.
1
15
10bit
Spindle No.1 Reject
1
14
11bit
Spindle No.1 Accept
1
13
12bit Current Warning
1
12
13bit Spindle in Bypass
1
11
14bit Sequence Output 3
1
10
15bit Sequence Output 2
1
9
Output
Word
No.02
0bit
Spindle No.3 BYP
1
24
1bit
Spindle No.3 ABN.
1
23
2bit
Spindle No.3 Reject
1
22
3bit
Spindle No.3 Accept
1
21
4bit
Spindle No.2 BYP
1
20
5bit
Spindle No.2 ABN.
1
19
6bit
Spindle No.2 Reject
1
18
7bit
Spindle No.2 Accept
1
17
8bit
Spindle No.5 BYP
1
32
9bit
Spindle No.5 ABN.
1
31
10bit
Spindle No.5 Reject
1
30
11bit
Spindle No.5 Accept
1
29
12bit
Spindle No.4 BYP
1
28
13bit
Spindle No.4 ABN.
1
27
14bit
Spindle No.4 Reject
1
26
15bit
Spindle No.4 Accept
1
25
Output
Word
No.03
0bit
Spindle No.7 BYP
2
8
1bit
Spindle No.7 ABN.
2
7
2bit
Spindle No.7 Reject
2
6
3bit
Spindle No.7 Accept
2
5
4bit
Spindle No.6 BYP
2
4
5bit
Spindle No.6 ABN.
2
3
6bit
Spindle No.6 Reject
2
2
7bit
Spindle No.6 Accept
2
1
8bit
Spindle No.9 BYP
2
16
9bit
Spindle No.9 ABN.
2
15
10bit
Spindle No.9 Reject
2
14
11bit
Spindle No.9 Accept
2
13
12bit
Spindle No.8 BYP
2
12
13bit
Spindle No.8 ABN.
2
11
14bit
Spindle No.8 Reject
2
10
15bit
Spindle No.8 Accept
2
9
:
CH. No.
Bit
Signal
Output CH.
No.16
0bit
8
1
…
15bit
8
32
These Output signals are user
configurable using the AFC User
Console Software and may be
programmed on any designated
bit.
The Output signal mapping
shown is only an EXAMPLE.
The signals may be programmed
for