4 ouput signals (plc-out) connector – FEC AFC1500 User Manual
Page 52
AFC1500 Multi-2 Unit Hardware Manual (Rev2.1)
PAGE 5 - 8
Chapter 5: Control Interfaces
5.3.4 Ouput Signals (PLC-OUT) Connector
The Multi-2 Unit is capable of providing over 570 Output signals to indicate the status of the
Multi-2 Unit and of all the AFC1500 SAN Controllers connected to it (up to 31 controllers). These
signals are user configurable using the AFC User Console Software and may be programmed on
any designated pin. Up to 8 separate output data “Banks” can be set up, each with 32 different
output signals. The Output “Bank” is then selected using the Data Select inputs (Data Select 0,
Data Select 1, Data Select 2).
FEC Standard* Output Layout
NO
Signal
Type**
Description
1
Total Reject
NO
Output when the fastening result is a REJECT.
2
Total Accept
NO
Output when the fastening result is a ACCEPT.
3
Abnormal
NO
Output when an Abnormal condition occurs.
4
Ready
NO
Output when the system is in the READY condition.
5
Busy
NO
System is in cycle
6
End
NO
Output when a fastening cycle is complete.
7
Sequence Output 0
NO
Output confirmation of SEQUENCE SELECT 0~4 input
selections.
8
Sequence Output 1
NO
9
Sequence Output 2
NO
10
Sequence Output 3
NO
11
Out Port 1
NO
These signals will output when the fastening sequence
reaches a step that has a [PLC OUTPUT] instruction
inserted.
12
Out Port 2
NO
13
Out Port 3
NO
14
Out Port 4
NO
15
Out Port 5
NO
16
Out Port 6
NO
17
Out Port 7
NO
18
Out Port 8
NO
19
Spindle in Bypass
NO
Output when any connected spindle is in Bypass
20
Current Limit Warning
NO
Active when the high current limit has been exceeded.
21
~
29
As Configured
NO
30
Always ON / Always OFF
NO
See “Output Data Banks” on following page
31
Always ON / Always OFF
NO
See “Output Data Banks” on following page
32
Always ON / Always OFF
NO
See “Output Data Banks” on following page
33
Output Signal Power
Common for output signal.
Sink Type
+0V
34
Output Signal Power
Source Type
+24V
*
This “Standard” layout is only provided as a guide. Any signal may be programmed on any pin using the
AFC Software.
The layout above is programmed standard from FEC. It contains only “Multi” or system signals as shown,
however, individual spindle signals are available and may be programmed (Ex. Individual spindle accept or reject
– See 4.7.3 for complete list of signals that may be programmed on these pins)
** Type: NO = (Normally Open)
For Output Signal definition see Section 4.7.3.