3 troubleshooting – FlexLink Elevator Руководство пользователя User Manual
Page 71

Technical maintenance
Create
d
by EBCCW
0
0
:06
63
5112204
7.3
Troubleshooting
If in doubt concerning the troubleshooting procedures below, contact FlexLink.
Troubleshooting guide
Symptom
Cause
Corrective action
The elevator does
not start
Peripheral equipment is not
connected. Power not on,
emergency stop button pressed,
door not closed, no signal from
peripheral equipment or circuit
breaker tripped.
Only personnel with technical
knowledge or equivalent sufficient
experience may conduct the
following actions.
•
Check circuit-breakers.
•
Check that peripheral equip-
ment has started.
•
Check that the power is on.
•
Check that the emergency stop
button is not pressed.
•
Check that the door switch is
activated.
•
Press "Reset".
•
Check that peripheral equip-
ment produces signals.
•
Press "Start".
No products to discharge
Wait for products to arrive.
Foreign matter on photo-electric
cells
Clean photo-electric cells.
Products fasten/
have fastened
Photo-electric cell faulty, out of
position or dirty
Only personnel with technical
knowledge or equivalent sufficient
experience may perform the
following actions.
1
Clean photo-electric cells.
2
Adjust photo-electric cells.
3
Check photo-electric cells'
position and operation, and
that they are connected.