Installation and adjustment

52

5112204

5.5.6.1.1

Adjustments

Photo-electric sensor

Adjust the sensor angle towards the reflector.

Adjust the reflector angle making the light beam from sensor hit the reflec-
tor 90 degrees against reflective surface.

The LED of sensor confirms reflection by reflector with not obstacles be-
tween. Any obstacle between should cause the LED to fall.

If anything blocks the signal between the sensor and reflector, the LED in-
dicator shall turn off.

Inductive sensor

Adjust the vertical distance between sensor and sensor flag on pallet.

5.5.6.2

Vertical motion

Figure 28 Inductive sensors

Inductive sensors are used at stop positions and low-speed stretches of the
vertical motion.

Retro-reflective photo-electric sensors are mounted in the upper part of
frame with reflectors mounted on the bottom plate of elevator. Their pur-
pose is to interlock vertical motion if obstacle is detected.

Vertical motion
position sensors

Lifting interlock sensor

Lifting interlock sensor
reflector