FlexLink Elevator Руководство пользователя User Manual
Page 60

Installation and adjustment
52
5112204
5.5.6.1.1
Adjustments
Photo-electric sensor
Adjust the sensor angle towards the reflector.
Adjust the reflector angle making the light beam from sensor hit the reflec-
tor 90 degrees against reflective surface.
The LED of sensor confirms reflection by reflector with not obstacles be-
tween. Any obstacle between should cause the LED to fall.
If anything blocks the signal between the sensor and reflector, the LED in-
dicator shall turn off.
Inductive sensor
Adjust the vertical distance between sensor and sensor flag on pallet.
5.5.6.2
Vertical motion
Figure 28 Inductive sensors
Inductive sensors are used at stop positions and low-speed stretches of the
vertical motion.
Retro-reflective photo-electric sensors are mounted in the upper part of
frame with reflectors mounted on the bottom plate of elevator. Their pur-
pose is to interlock vertical motion if obstacle is detected.
Vertical motion
position sensors
Lifting interlock sensor
Lifting interlock sensor
reflector