beautypg.com

Adjustment on – FlexLink Elevator Руководство пользователя User Manual

Page 61

background image

Installation and adjustment

Create

d

by EBCCW

0

0

:06

53

5112204

5.5.6.2.1

Adjustment

Vertical motion sensors

Figure 29 Vertical motion sensors

The low speed and stop sensors for up and down must be adjusted in re-
lation to motion speed and flag length.

The distance between low speed sensor and corresponding stop sensor is
affected by:

Flag length. Distance between sensors may not exceed flag
length on lift cage. If not fulfilled, the lift cage will loose the low
speed sensor, thus accelerating to high speed the moments be-
fore reaching stop sensor.

Motion speed/ramp time.

1

The combination of high speed, ramp time and distance between
sensors should be such that the lift cage successfully ramps down
to low speed before reaching stop sensor.

2

The combination of low speed and ramp time should be such that
the lift cage successfully ramps down to stop on the stop sensor
when the stop sensor is activated.

Reflector

Interlocking

Low speed
area

Low
speed

Up

Reflector

Interlocking

Low speed
area

Low
speed

Down

Vertical motion

Lift cage
sensor flag