FlexLink Elevator Руководство пользователя User Manual
Page 36

Introduction function and components
28
5112204
3.2.1.4
Guards
The elevator consists or moving parts that can cause injury. Feed-in and
discharge are covered by stationary and openable guards. The elevator
may not be operated if the door switch is inoperable or if a stationary guard
is improperly fitted.
Stationary guards
The elevator is protected by stationary guards of clear PC and aluminium.
These guards must be correctly fitted when the elevator is in service. The
stationary guards must be in place when the power is on.
Openable guard
The elevator is equipped with a service door for accessing the interior. This
door is equipped with a door switch. If the door is opened during operation,
power to the elevator motors is disconnected (stop category 0 according to
EN 60204-1). The door switch is a part of the safety system and may under
no circumstances be by passed or in any other way made inoperable. Once
the door is closed, the elevator can be reset and started.
.
Warning: Stop the elevator before opening the door. Do not open
the door for the purpose of stopping the elevator.
Figure 11 Safety switch, door