Instructions for use
Create
d
by EBCCW
0
0
:06
59
5112204
Stop procedure
Quick stop instruction: Press several times during one second. The eleva-
tor will stop immediately/quickly. It will not finish motions in progress.
Controlled stop instruction: Press once per second. The elevator will finish
ongoing motions before stopping. While stopping, the "Start"-indication
flash quickly (2 Hz). When the elevator is stopped the "Start"-indication is
off.
Emergency stop
Emergency stop must not be used for normal stop. It should be used in
case of emergency. Emergency stopping may cause the whole line to
emergency stop. An emergency stop of the elevator disconnect parts of the
electric power. A certain amount of manual labour may be required to get
the elevator back into normal run.
Opening door as stop
The door must not be used for normal stop. It should be used in case of
emergency or when the elevator already is normally stopped. Opening the
door during production will have the same effect on elevator as an emer-
gency stop. See above.
Alarm
During normal state the "Reset" -indication has steady light. At the occa-
sion of alarm the indication will start flashing until alarm is reset. Press "Re-
set" in order to reset alarm. The flashing turns into steady light if alarms are
reset.
6.2
Manual operation
The elevator's vertical motion can be manually adjusted in stopped state.
Alarms must be reset. Stop the elevator, wait until it is stopped and adjust
the lift cage's vertical position up/down using the 3-position switch. The mo-
tion is interlocked to avoid running past the up-and down-sensors. If the el-
evator is run upwards it will stop automatically when the up-sensor is acti-
vated, which is an advantage when verifying an adjusted sensor-position,
checking that lift cage and adjacent conveyor are in level thus making the
transition smooth. The motion downwards is not affected by the up-sensor.
Occasionally it is necessary to run past the up-and down-sensors, for ex-
ample at a crash-situation. In order to realize a run past the up-and down-
sensors keep "Stop"-button pressed.
Manual operation, upward direction: Turn the switch to the left.
Manual operation, downward direction: Turn the switch to the right.
To return to operation in automatic mode: Leave the switch in neutral posi-
tion and press "Start"-button.