beautypg.com

7 technical maintenance, 1 check and control procedures, 1 daily maintenance – FlexLink Elevator Руководство пользователя User Manual

Page 68: 2 monthly maintenance, 3 maintenance performed every third month, 7technical maintenance

background image

Technical maintenance

60

5112204

7

Technical maintenance

Technical maintenance is an important part of this manual. Good mainte-
nance will lead to cost reduction, because defects can be timely recognised
and solved. This section starts with a troubleshooting list, subsequently a
maintenance schedule is set up in section 7.2 on page 61 describes differ-
ent maintenance activities.

During carrying out any activities on the elevator make sure that the main
switch has been switched off, so that there is no voltage on the machine.

7.1

Check and control procedures

7.1.1

Daily maintenance

Check for abnormal sound/heat

Check for dust and particles (especially on sensors)

7.1.2

Monthly maintenance

Check function of the emergency stop device.

Check chain tension and lubrication.

Check the roller chain guides.

Check drive chain for wear and tension.

Check the bearings.

7.1.3

Maintenance performed every third month

Check threaded fasteners.

Check that the elevator is running smoothly.

Check attachment of the carriers.

Check that the chain, cog belt and carriers/lifting device are free
from damage.