beautypg.com

3 motor, 4 chain guide profile – FlexLink Elevator Руководство пользователя User Manual

Page 70

background image

Technical maintenance

62

5112204

7.2.3

Motor

For standard elevators without field distributor the main switch of the cabi-
net needs to be switched off and locked prior to motor replacement.

Turn off electrical main switch of module located on control box
door.

Check no voltage in motor.

Replace motor electrically and mechanically.

Set all DIP switches and thumb wheels in the cover of the motor
according to replaced motor.

Connect the internal cables on the terminal block according to ei-
ther the electrical documentation or the replaced motor.

The vertical drive for advanced versions is connected to the field distributor
through a fast connector cable to facilitate service.

Turn off the switch on the field distributor and lock it prior to dis-
connecting the fast connector to the motor.

Set all DIP switches and thumb wheels in the cover of the motor
so that they are the same positions as the one to be replaced.

Connect the internal cables on the terminal block according to ei-
ther the electrical documentation or the replaced motor.

Plug in the connector and tighten it before turning on the power
switch.

To assure trouble-free operation, the motor and gears must be maintained
according to manufacturer's user manual.

For more information, see manufacturer manual.

7.2.4

Chain guide profile

The chain guide profile shall be replaced as necessary.

See

Recommended spare parts on page 67

.