Guards

.

The elevator consists of moving parts that can cause injury.

Feed-in and feed-out areas around the elevator are unprotected; they must
be protected by, for example, the installation of tunnels or similar devices.

The elevator may not be operated if the door switch is inoperable or if a sta-
tionary guard is improperly fitted.

Stationary guards

The elevator is protected by stationary guards of clear PC and aluminium.

Openable guard

The elevator is equipped with a service door for accessing the interior. This
door is equipped with a door switch. If the door is opened during operation,
power to elevator motors is disconnected (stop category 0 according to EN
60204-1).

.

Stop the elevator before opening the door. Do not open the door for
the purpose of stopping the elevator.

The door switch does not disconnect power to the machine.

1.3.4

Noise level

.

The noise level produced by the elevator is under 70 dB(A).

1.3.5

Electrical cabinet

.

The voltage in the electrical cabinet is 400 V or 480 V, depending on ver-
sion. Ensure that the electrical cabinet is closed and locked after working
in the electrical cabinet.

Never bypass the safety system.

The electrical cabinet can only be opened using a tool.

Before working in the electrical cabinet, the main switch to the motor must
be turned off and locked. The key is retained by the service technician until
work is finished.