4.3.4 Charger Module – Control Interface Connector

The Charger Module – Control Interface Connector is connected between

the charger module and ECM with Sense/Power leads connected to the APU

Output DC Bus. The interface control is a 4-pin (2x2 row) Universal Mini Mate-

’N’-Lok style male connector. See Fig. 4-1 for location.

Pin

Description

Function

1

Ignition Battery (+) Sense (YELLOW) wire.

Senses DC Charge on ignition

battery, adjusts charger for

correct voltage.

2

Inverter Battery (+) RED wire.

Input power to

charger module, operates on

36 or 48VDC battery packs to

charge ignition battery.

3

ECM Charger Control ORANGE

ECM Turns charger ON by

applying a LOW signal to this

pin (referenced to ignition

battery negative).

4

Inverter Battery NEGATIVE BLACK wire

NEGATIVE Input power to

charger module, operates on

36 or 48VDC battery packs to

charge ignition battery.