3.1 Cleaning and Lubrication
The Auxiliary Power Unit, being a gas-driven, air-cooled, combustion engine,
requires periodic maintenance. Maintenance items may include: changing the
engine oil at recommended intervals; cleaning and/or replacing the engine air
filter; checking the intake and exhaust vents and fans for proper operation; and
cleaning and/or replacing the enclosure filters.
NOTE
:
A corrosion-inhibiting coating (such as LPS3 by LPS Corp.)
must be used on all exposed connector assemblies and
reapplied annually per the manufacturers instructions.
A
B
C
D
F
G
H
E
I
J
A
Air filter cover
B.
Gas Hazard Sensor
C.
Mounting bracket for Water Intrusion and Pad Shear Sensor
D.
Fuel Demand Regulator
E.
Manometer Port (for test purposes only)
F.
Run Time Indicator
G.
Oil Filter
H.
Dual-Fuel Load Block
I.
Rectifier Cover
J.
Oil Dipstick
K.
Ignition Battery Charger
L.
DC Output Connector
M.
Ignition Starter Battery Cable
K
M
L
Fig. 3-1 APU compartment
- AlphaCell GelCell Series (32 pages)
- FXM 650, 1100, 2000 UPS (96 pages)
- Cordex 48-1.2kW (68 pages)
- Radium MiniBay (57 pages)
- Fiber Backhaul Enclosure (FBE) (19 pages)
- FBE2322 Enclosure System (38 pages)
- FlexNet PMR, GMR Series (49 pages)
- Te25xh (38 pages)
- FlexNet MPS48-12M - Technical Manual (33 pages)
- FlexNet MPS48-12M - Quick Start Guide (2 pages)
- FlexNet ELPM 300-48D (25 pages)
- FlexNet FMPS (40 pages)
- FlexPoint AX Series (34 pages)
- FlexPoint FPR1207-F - Technical Manual (18 pages)
- FlexPoint FPR1207-F - Quick Start Guide (2 pages)
- AlphaGen PN-6x-T 7.5kW 48VDC - Installation and Operation Manual (79 pages)
- AlphaGen CE-3x2 5K-T 48Vdc (95 pages)
- AlphaGen PN-6x-T 7.5kW 48Vdc (95 pages)
- AlphaGen 3.5_5.0kW Kohler COM5 (80 pages)
- Security Bar Field For UPE-3, UPE-6, UPE-M3, UPE-M6, PN Series and CE Series (2 pages)
- AMPS80 HP (116 pages)
- 255A Bypass Switch (24 pages)
- AMP24 HP (108 pages)
- FXM350_Micro350 UPS (112 pages)
- CFR 600, CFR 600XT, CFR 1000 (70 pages)
- BPS Series Bypass Switch (36 pages)
- CFR Intelligent Interface Device (54 pages)
- CFR Redundant Control Unit (23 pages)
- CFR 5000, CFR 5000RM (88 pages)
- CFR 3000, CFR 3000RM (86 pages)
- CFR 1500, CFR 1500RM (83 pages)
- CFR 1500, CFR 2000, CFR 2500, CFR 3000 (76 pages)
- Continuity: 1000_2000_3000 (48 pages)
- Continuity Battery Pack (20 pages)
- Continuity: 6K_10K (52 pages)
- Micro, Micro XL, Micro XL3 UPS (99 pages)
- Micro Secure UPS (80 pages)
- Te17 (32 pages)
- Te45 (68 pages)
- Te41, 48V (76 pages)
- Te41, 24V (72 pages)
- Te43 (60 pages)
- AlphaGuard AG-CMT Installation (2 pages)
- AlphaGuard AG-CMT-3SC_4SC-P (2 pages)
- Digital Midtron DM-3200 AT (2 pages)