3. Maintenance

53

031-132-B0-001 Rev. A

TM

©2000

3.12 Muffler Replacement Procedure

Allow 15 minutes for completion of procedure.

Tools required:

#2 Phillips screwdriver or hand drill

1/2” deep-well socket wrench

6” extension

3/8” drive

Removal and replacement procedure:

NOTE:

Allow the unit to cool thoroughly before beginning procedure.

2. Use the 1/2” deep-well socket to

remove the upper flange U-bolt

assembly.

3. Use the 5/16” wrench to remove the

“Cable-5 Flexi-mounts”. Once the

mounting hardware for the “Flexi-

mounts” have been removed, the

muffler is ready for removal.

1. Remove fastening hardware on muffler

access panel.