3. Maintenance

45

031-132-B0-001 Rev. A

TM

©2000

Disconnect the sensor from the wire

harness and replace with the new

sensor. Add the opposite piece of the

hook and loop fastener, and reinstall

the sensor.

End of Procedure

3.6

Replacing GAS HAZARD Sensor, continued

Removal and replacement procedure, continued:

NOTE:

Verify the replacement gas sensor is calibrated to detect

the appropriate gas (i.e., Propane or Natural Gas).