Xylem System 5000 User Manual User Manual
Page 105

103
General Setup
System 500
0
™
If None is selected, all Tasks will
be run regardless of the measured
battery voltage level. If the second
option is selected, Tasks will only be
run when the voltage level is within
the given range. If the voltage level
is outside of the specified range,
the system will simply schedule the
next scan and re-measure when
that time arrives.
GOES Radio
battery voltage level. If the second option is selected, GOES Transmissions will only be
scheduled and run when the voltage level is within the given range. If the voltage level is
outside of the specified range, the system will skip the current transmission scheduling and
re-measure on the next scan. Note that some GOES Radios have a built-in cut-off voltage
independent of this check.
Cut-off Temperature
Allows a minimum and maximum temperature range that must be met to continue normal
operation. If None is selected, all Tasks will be run regardless of the measured temperature. If the
second option is selected, Tasks will only be run when the measured temperature is within the
given range. If the temperature is outside of the specified range, the system will simply schedule
the next scan and re-measure when that time arrives. The temperature is retrieved and checked
at the beginning of each scan period.
If None is selected, all GOES
Transmissions will be scheduled
and run regardless of the measured