Table 80 snmp interfacetraps – ZyXEL Communications ES-2108 Series User Manual
Page 206
![background image](/manuals/227469/206/background.png)
Chapter 27 Access Control
ES-2108 Series User’s Guide
206
fanspeed
FanSpeedEventOn
1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This
trap
is sent when the fan speed
goes above or below the normal
operating range.
FanSpeedEventClear
1.3.6.1.4.1.890.1.5.8.xx.31.2.2 This trap is sent when the fan speed
returns to the normal operating
range.
temperature
TemperatureEventOn
1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This trap is sent when the
temperature goes above or below
the normal operating range.
TemperatureEventClear
1.3.6.1.4.1.890.1.5.8.xx.31.2.2 This trap is sent when the
temperature returns to the normal
operating range.
voltage
VoltageEventOn
1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This
trap is sent when the voltage
goes above or below the normal
operating range.
VoltageEventClear
1.3.6.1.4.1.890.1.5.8.xx.31.2.2 This
trap is sent when the voltage
returns to the normal operating
range.
reset
UncontrolledResetEventOn
1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This trap is sent when the Switch
automatically resets.
ControlledResetEventOn
1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This trap is sent when the Switch
resets by an administrator through a
management interface.
RebootEvent
1.3.6.1.4.1.890.1.5.1.1.2
This trap is sent when the Switch
reboots by an administrator through
a management interface.
timesync
RTCNotUpdatedEventOn
1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This
trap is sent when the Switch
fails to get the time and date from a
time server.
RTCNotUpdatedEventClear
1.3.6.1.4.1.890.1.5.8.xx.31.2.2 This trap is sent when the Switch
gets the time and date from a time
server.
intrusionlock
IntrusionLockEventOn
1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This trap is sent when intrusion lock
occurs on a port.
loopguard
LoopguardEventOn
1.3.6.1.4.1.890.1.5.8.xx.31.2.1
This trap is sent when loopguard
shuts down a port.
Table 79 SNMP System Traps (continued)
OPTION
OBJECT LABEL
OBJECT ID
DESCRIPTION
Table 80 SNMP Interface Traps
OPTION
OBJECT LABEL
OBJECT ID
DESCRIPTION
linkup
linkUp
1.3.6.1.6.3.1.1.5.4
This trap is sent when the
Ethernet link is up.
LinkDownEventClear
1.3.6.1.4.1.890.1.5.8.xx.31.2.2
This trap is sent when the
Ethernet link is up.
linkdown
linkDown
1.3.6.1.6.3.1.1.5.3
This trap is sent when the
Ethernet link is down.
LinkDownEventOn
1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This trap is sent when the
Ethernet link is down.