Texas Instruments MSP430x4xx User Manual
Page 398
![background image](/manuals/211207/398/background.png)
ADC12 Registers
20-22
ADC12
MSC
Bit 7
Multiple sample and conversion. Valid only for sequence or repeated modes.
0
The sampling timer requires a rising edge of the SHI signal to trigger
each sample-and-conversion.
1
The first rising edge of the SHI signal triggers the sampling timer, but
further sample-and-conversions are performed automatically as soon
as the prior conversion is completed.
REF2_5V
Bit 6
Reference generator voltage. REFON must also be set.
0
1.5 V
1
2.5 V
REFON
Bit 5
Reference generator on
0
Reference off
1
Reference on
ADC12ON
Bit 4
ADC12 on
0
ADC12 off
1
ADC12 on
ADC12OVIE
Bit 3
ADC12MEMx overflow-interrupt enable. The GIE bit must also be set to
enable the interrupt.
0
Overflow interrupt disabled
1
Overflow interrupt enabled
ADC12
TOVIE
Bit 2
ADC12 conversion-time-overflow interrupt enable. The GIE bit must also be
set to enable the interrupt.
0
Conversion time overflow interrupt disabled
1
Conversion time overflow interrupt enabled
ENC
Bit 1
Enable conversion
0
ADC12 disabled
1
ADC12 enabled
ADC12SC
Bit
0
Start conversion. Software-controlled sample-and-conversion start.
ADC12SC and ENC may be set together with one instruction. ADC12SC is
reset automatically.
0
No sample-and-conversion-start
1
Start sample-and-conversion