Tactl, timer_a control register – Texas Instruments MSP430x4xx User Manual
Page 229
Timer_A Registers
12-20
Timer_A
TACTL, Timer_A Control Register
15
14
13
12
11
10
9
8
Unused
TASSELx
rw−(0)
rw−(0)
rw−(0)
rw−(0)
rw−(0)
rw−(0)
rw−(0)
rw−(0)
7
6
5
4
3
2
1
0
IDx
MCx
Unused
TACLR
TAIE
TAIFG
rw−(0)
rw−(0)
rw−(0)
rw−(0)
rw−(0)
w−(0)
rw−(0)
rw−(0)
Unused
Bits
15-10
Unused
TASSELx
Bits
9-8
Timer_A clock source select
00
TACLK
01
ACLK
10
SMCLK
11
Inverted TACLK
IDx
Bits
7-6
Input divider. These bits select the divider for the input clock.
00
/1
01
/2
10
/4
11
/8
MCx
Bits
5-4
Mode control. Setting MCx = 00h when Timer_A is not in use conserves
power.
00
Stop mode: the timer is halted
01
Up mode: the timer counts up to TACCR0
10
Continuous mode: the timer counts up to 0FFFFh
11
Up/down mode: the timer counts up to TACCR0 then down to 0000h
Unused
Bit 3
Unused
TACLR
Bit 2
Timer_A clear. Setting this bit resets TAR, the TACLK divider, and the count
direction. The TACLR bit is automatically reset and is always read as zero.
TAIE
Bit 1
Timer_A interrupt enable. This bit enables the TAIFG interrupt request.
0
Interrupt disabled
1
Interrupt enabled
TAIFG
Bit 0
Timer_A interrupt flag
0
No interrupt pending
1