Lcdavctl0, lcd_a voltage control register 0 – Texas Instruments MSP430x4xx User Manual
Page 375
LCD_A Controller Operation
19-25
LCD_A Controller
LCDAVCTL0, LCD_A Voltage Control Register 0
7
6
5
4
3
2
1
0
Unused
R03EXT
REXT
VLCDEXT
LCDCPEN
VLCDREFx
LCD2B
rw−0
rw−0
rw−0
rw−0
rw−0
rw−0
rw−0
rw−0
Unused
Bit 7
Unused
R03EXT
Bit 6
V5 voltage select. This bit selects the external connection for the lowest
LCD voltage. R03EXT is ignored if there is no R03 pin available.
0
V5 is AV
CC
1
V5 is sourced from the R03 pin
REXT
Bit 5
V2 − V4 voltage select. This bit selects the external connections for
voltages V2 − V4.
0
V2 − V4 are generated internally
1
V2 − V4 are sourced externally and the internal bias generator is
switched off
VLCDEXT
Bit 4
V
LCD
source select
0
V
LCD
is generated internally
1
V
LCD
is sourced externally
LCDCPEN
Bit 3
Charge pump enable.
0
Charge pump disabled.
1
Charge pump enabled when VLCDx > 0 or VLCDREFx > 0 and
VLCDEXT = 0
VLCDREFx
Bits
2−1
Charge pump reference select
00
Internal
01
External
10
Reserved
11
Reserved
LCD2B
Bit 0
Bias select. LCD2B is ignored when LCDMx = 00.
0
1/3 bias
1
1/2 bias