beautypg.com

9 auto adjust time, Auto adjust time, Sntp server setup – Omron CS1W-ETN21 User Manual

Page 99

background image

74

Auto Adjust Time

Section 3-9

For details, refer to SECTION 3 Mail Receive Function in the Operation Man-
ual Construction of Applications
.

3-9

Auto Adjust Time

SNTP Server Setup

Item

Contents

Default

Get the time
information from
the SNTP
server

If this option is selected, the CPU Unit's clock is set to
the time at the SNTP server's clock.

The clock can be changed only for the CPU Unit to
which the Ethernet Unit is mounted.

Not
checked

Auto Adjust
Time

Set the time at which the SNTP server is to be
accessed to synchronize the clocks.

When the time that is set here arrives, the SNTP
server is accessed and the CPU Unit clock is
adjusted to match the SNTP server clock.

0:0:0

Server specifi-
cation type

Select whether the SNTP server used for automatic
clock adjustment is to be specified by IP address or
by host domain name (i.e., by host name).

IP Address

IP Address

Set the IP address for the SNTP server that is to be
used for automatic clock adjustment.

This setting is enabled only when server specification
by IP address has been selected.

0.0.0.0

Host name

Set the host domain name (i.e., the host name) for
the SNTP server that is to be used for automatic
clock adjustment.

This setting is enabled only when server specification
by host name has been selected.

None

Port No.

Set the port number for connecting to the SNTP
server that is to be used for automatic clock adjust-
ment. This setting does not normally need to be
changed.

0
(Number
123 is
used.)