Udp close request, 3-12 udp close request – Omron CS1W-ETN21 User Manual
Page 196
![background image](/manuals/203937/196/background.png)
171
Command/Response Reference
Section 7-3
Results Storage Area Response Codes
7-3-12 UDP CLOSE REQUEST
Requests processing to close a socket.
Command Block
Response Block
Results Storage Format
Parameters
Socket Option (Command)
The socket option specified as 1 byte. The setting is not valid for this com-
mand. Set to 0.
UDP Socket Number
(Command)
The UDP socket number to be closed specified as 1 byte between 1 and 8.
1100
UDP socket number or number of bytes sent is out of range.
The destination IP address is 0.
Local UDP port number is 0.
1101
The variable type for the results storage area is out of range.
1103
Non-zero bit address specified for the results storage area.
220F
Specified socket is currently sending.
2210
The specified socket is not open.
2211
High traffic at Unit; cannot execute service.
Response code
Description
0000
Normal
003E
Internal buffer cannot be reserved due to high reception load
(ENOBUFS).
0042
The send destination IP address is a broadcast address and
the number of bytes sent exceeds 1,472. (EMSGSIZE)
004C
Incorrect network number.
Incorrect destination IP address (EADDRNOTAVAIL).
004E
Incorrect destination IP address (ENETUNREACH).
No network number in IP router table.
Router incorrectly set.
0051
Router incorrectly specified.
Incorrect destination IP address (EHOSTUNREACH).
Response code
Description
Command
code
Socket option
UDP socket number
27 04
Results storage area
Response
code
Command
code
27 04
Response code