207

Error Log

Section 8-3

03C4

Server connection error

00: DNS

01: SMTP

02: POP3

03: SNTP

01: Specified
host does not
exist

02: No ser-
vice at speci-
fied host

03: Timeout

04: Closed
unilaterally by
host

05: Cannot
connect
because
account infor-
mation does
not match

06: Host
name resolu-
tion error

07: Transmis-
sion error

08: Recep-
tion error

09: Other
error

Take either of the following mea-
sures.

• Correct the settings for each

server.

• Inspect the communications path

(Ethernet Unit, cable connec-
tions, hub, router, server), and
correct the situation that is caus-
ing the error.

---

03C5

Mail communications error

F101: Mail too large

F102: Mail received from
non-specified address

F103: Mail subject error

F104: Non-specified com-
mand received

F106: Mail format (header)
error

F107: Mail format (body)
error

F201: Parameter error

F301: Decoding error

F302: File attachment error
(filename error, data format
error, I/O memory write size
error)

F303: No attached file

F304: Non-specified file
attachment received

F305: File attachment too
large

Other: FINS error response
code

Refer to the Operation Manual,
Construction of Applications: Cre-
ating FINS Applications
, and cor-
rect the remote node (i.e., the
application on the personal com-
puter).

---

03C6

Clock data write error

0001: Clock data could not
be refreshed because of a
CPU Unit error.

Clear the CPU Unit error.

---

0002: Clock data could not
be refreshed because the
CPU Unit could not write
clock data in that operation
mode.

Refer to the Operation Manual,
Construction of Applications:
Automatic Clock Adjustment
Function
, and check the operat-
ing conditions.

---

Error

code

Meaning

Detailed error code

Correction

EE-

PROM

1st byte

2nd byte