beautypg.com

Udp receive request, 3-10 udp receive request – Omron CS1W-ETN21 User Manual

Page 193

background image

168

Command/Response Reference

Section 7-3

Results Storage Area Response Codes

7-3-10 UDP RECEIVE REQUEST

Requests that data be sent from a UDP socket.

Command Block

Response Block

Results Storage Format

Parameters

Socket Option (Command)

The socket option specified as 1 byte. The setting is not valid for this com-
mand. Set to 0.

UDP Socket Number
(Command)

The UDP socket number to receive data specified as 1 byte between 1 and 8.

Results Storage Area
(Command)

The area in which the results of the command execution are stored. The first
byte specifies the memory area and data type (variable type). The 2nd to 4th
bytes specify the beginning address of the results storage area. Refer to
page 158 for details about the variable types and addresses that can be spec-
ified.

1002

Command too small

1100

UDP socket number is out of range.

Local UDP port number is 0.

1101

The variable type for the results storage area is out of range.

1103

Non-zero bit address specified for the results storage area.

220F

Specified socket is already open or is being closed.

2211

High traffic at Unit; cannot execute service.

Response code

Description

0000

Normal

003E

Internal buffer cannot be reserved due to high receive load
(ENOBUFS).

0049

Duplicate UDP port number (EADDRINUSE).

Response code

Description

Number

of reception

bytes

Timeout

value

Socket option

27 02

Command

code

UDP socket number

Results storage area

Response

code

Command

code

27 02

Source IP address

Response

code

Source UDP

port number

Number of

reception

bytes

Received data

Received bytes