Command/Response Reference

Section 7-3

Command Block

Parameters

Test Data (Command)

This command specifies the data to be sent to the specified nodes. Up to
1,460 bytes can be specified.

Precautions

No response is made to this command.

When using this command, set the FINS header parameters (or the control
data for the CMND(194) instruction) as follows:

Destination node address:

FF (broadcast data)

Destination unit address:

FE (Ethernet Unit)

Response/no response flag:

1 (no response)

7-3-7

ERROR LOG READ

Reads the error log.

Command Block

Response Block

Parameters

Beginning Record Number
(Command)

The first record to be read. The first record number can be specified in the
range between 0000 and 003F (0 to 63 decimal) where 0000 is the oldest
record.

Number of Records
(Command, Response)

The number of records to read is specified between 0001 and 0040 (1 to 64
decimal) in the command. The response returns the actual number of records
read.

Maximum Number of
Stored Records
(Response)

The maximum number of records that can be stored in the error log. Care is
required as the error log differs according to the type of PC or CPU Bus Unit.
In an Ethernet Unit, the maximum number of stored records is fixed at 40 (64
decimal).

Number of Stored
Records (Response)

The number of records stored at the time the command is executed is
returned.

08 03

Command

code

1,460 bytes max.

Test data

21 02

Beginning

record

number

Number

of

records

Command

code

21 02

Maximum

number

of stored

records

Number

of stored

records

Number

of

records

10 bytes

10 bytes

Error log data

Response

code

Command

code

Error log data