Omron CS1W-ETN21 User Manual
Page 130
105
IP Addresses in FINS Communications
Section 5-2
applications, such as mail servers, are normally allocated fixed IP addresses.
Ethernet Units in PLC systems are also allocated fixed IP addresses.
Simultaneously Running Multiple Applications on a Personal Computer
In communications involving previous models, multiple communications appli-
cations were configured on personal computers according to data accessing
uses, and the fact that no more than one UDP port number for FINS commu-
nications could be used on any given computer created a problem. This
Ethernet Unit provides a practical solution with an internal table that pairs
remote nodes (applications) with FINS node addresses, enabling dynamic
changes.
FINS/UDP
Communications Method
FINS nodes are allocated individually for each application on the computer,
and the respective FINS/UDP port numbers that are used are also allocated
individually. When FINS/UDP FINS commands are sent from individual appli-
cations to the Ethernet Unit, the respective remote IP addresses and remote
port numbers in the internal table are dynamically changed.
FINS/TCP
Communications Method
With this method as well, FINS nodes are allocated individually for each appli-
cation on the computer, and the respective FINS/TCP port numbers that are
used are also allocated individually. Each application is positioned with a
FINS/TCP client, and requests the opening of a connection with the Ethernet
Unit's FINS/TCP server. When the connection is established, the respective
remote IP address and remote port number in the internal table are dynami-
cally changed.
5-2-4
Related Products and Communications/Setting Methods
Models Supporting Automatic Generation Method (Dynamic)
Product
Model/Series/
Version
Supports automatic
generation method
(dynamic)?
CS-series Ethernet
Unit
100BASE-TX
CS1W-ETN21
Yes
10BASE-5
CS1W-ETN01
No: Set by automatic
generation method or
combined method. Com-
munications are not pos-
sible with personal
computers with variable
IP addresses.
10BASE-T
CS1W-ETN11
CJ-series Ethernet
Unit
100BASE-TX
CJ1W-ETN21
Yes
10BASE-T
CJ1W-ETN11
No: Set by automatic
generation method or
combined method. Com-
munications are not pos-
sible with personal
computers with variable
IP addresses.
CV/CVM1-series
Ethernet Unit
10BASE-5
CV500-ETN01
FinsGateway
Version 4.xx or
lower
Version 2003 or
higher
Yes
Programmable Terminal
NS Series
No: Set manually so that
automatic settings can be
used with the automatic
generation method.
Open Network Controller (ONC)
---