beautypg.com

600r server – Nortel Networks CallPilot NN44200-700 User Manual

Page 50

background image

50

Chapter 3 Hardware troubleshooting

The system detects the
MPB96 board only partially,
and Configuration Wizard
does not run.

The MPB96 board is configured incorrectly from the clocking
point of view.
Contact your Nortel support representative for assistance.

The system detects the
MPB96 board, but does
not correctly load the DSP
information at startup.

The cache.bin file in the D:\nortel\hardware\dsp\c52\ folder is
corrupted.
Rerun the Configuration Wizard to reflash the DSPs.

600r server

The 600r server is based on an Intel Chesnee server platform with
advanced self-troubleshooting mechanisms. You can troubleshoot errors
by observing multiple areas:

Visual – front or rear panel LEDs

Audio or Sound – beeps or increased fan noise pitch

Software – remotely using network intelligent modules (SNMP and/or
event logs).

If the system is powered on, you can access error reporting using the
CallPilot image CD/DVD SEL viewer tool (if the system does not boot into
Windows). This tool reports all hardware events and saves them as a text
file on a USB media.

Server LEDs

The LEDs indicate the state of your server and can help you troubleshoot
startup problems. The following tables provide useful information about the
external and internal LEDs.

Front panel LEDs

LED

Functional Description

CRT

A critical system fault is an error or event that
has a fatal system impact. The system cannot
continue to operate.

MJR

A major system fault is an error or event that
has a discernible impact on system operation.
The system can continue to operate but with
reduced performance or features.

Nortel CallPilot

Troubleshooting Reference Guide

NN44200-700

01.05

Standard

5.0

26 June 2007

Copyright © 2007, Nortel Networks

.