201i server

System troubleshooting

Trouble

Action

The system emits beep
codes.

The state of the PC chip set is associated with beep codes. Some
codes indicate relatively harmless failure situations that allow you
to start up the CallPilot server, even though the system is not fully
functional unless you solve the trouble.

Some beep codes indicate catastrophic failures that cannot be
easily resolved at the customer site. For example, the series of
beep codes 1-3-3-1 indicates a defective or missing memory DIMM.
Declare the system an out-of-box failure (OBF) and return it to the
channel partner.

Note: The 201i server emits one pulse beep at startup. This is a
normal beep and does not indicate a system failure.