1005r server

45

Memory Size Decreased

The memory size has decreased since the last boot. If you have
not removed any memory, then the memory may be faulty.

Memory Size Increased

The memory size has increased since the last boot. If you have
not added any memory, there is a problem with the system.

Memory Size Changed

The memory size has changed since the last boot. If you did not
add or remove any memory, then the memory may be faulty.

No Boot Device Available

The system did not find a device to boot from.

Off Board Parity Error

A parity error occurred on an offboard card. This error is followed
by the card address.

On Board Parity Error

A parity error occurred in onboard memory. This error is followed
by the card address.

Parity Error

A parity error occurred in onboard memory at an unknown
address.

NVRAM / CMOS /
PASSWORD cleared by
Jumper

NVRAM, CMOS, and passwords have been cleared. Power the
system down and remove the jumper.

Pressed

The CMOS is ignored and NVRAM is cleared. You must enter
Setup.

System troubleshooting

Trouble symptom

Action

The system boots, the fans turn at high speed
but do not return to normal speed. The system
is extremely noisy.

Two possible causes are:

One or more fans are faulty and you need
to replace the fan module. For instructions,
see the 1005r Server Maintenance and
Diagnostics Guide
(NN44200-704).

An IMM module is faulty or incorrectly
programmed. Reflash the system board
F/W with Nortel-approved BMC and
FRU/SDR and try again.

If neither of the above actions resolves the
problem, replace the server (as the IMM board
is a non-FRU item).

The system boots and beeps, but there is no
video. (In some cases a red LED appears on
the front cover).

Refer to the error and beep codes or contact
Nortel at

http://www.nortel.com/support

The system boots but a red CRT LED and an
amber PWR LED appears.

One power supply is faulty, or the AC cable is
unplugged (or faulty).

Nortel CallPilot

Troubleshooting Reference Guide

NN44200-700

01.05

Standard

5.0

26 June 2007

Copyright © 2007, Nortel Networks

.