Installing the bcm50 unit on the rack-mount shelf – Nortel Networks BCM50 User Manual
Page 83
Chapter 7 Installing the main unit
83
Installation and Maintenance Guide
Use the following procedures to install a BCM50 unit in a rack:
•
To install the rack-mount shelf in an equipment rack
•
To install the BCM50 unit on the rack-mount shelf
•
To install the power supply on the rack-mount shelf
To install the rack-mount shelf in an equipment rack
1
Determine the location in the rack where you want to install the BCM50 unit.
2
Position the rack-mount shelf in the rack.
3
Align the holes in the rack-mount shelf with the holes in the equipment rack rails.
4
Fasten the rack-mount shelf to the rack using the four rack screws (supplied with the
rack-mount kit). See the figure
Fasten the rack-mount shelf to an equipment rack
5
Installing the BCM50 unit on the rack-mount shelf
Figure 35 Fasten the rack-mount shelf to an equipment rack
Installing the BCM50 unit on the rack-mount shelf
The rack-mount shelf has slots molded into its surface to which you attach the BCM50 units. By
attaching the BCM50 units to these slots, you can prevent someone from accidently knocking
them off the rack-mount shelf.
Caution: To keep the BCM50 system operating at the optimal internal temperature, keep
the top, sides, and rear clear of obstructions and away from the exhaust of other equipment.
Place no objects, except other BCM50 units, on top of the main unit.