beautypg.com

Test insertion loss measurement – Nortel Networks BCM50 User Manual

Page 122

background image

122

Chapter 11 Installing the analog terminal adapter

NN40020-302

Figure 57 ATA2 back view

Test insertion loss measurement

The maximum loss for ATA2 to Central Office (CO) configuration must not exceed 10 dB. See the
figure

Insertion loss from the CO to the analog telephone

on page 122.

Figure 58 Insertion loss from the CO to the analog telephone

Measure the total insertion loss between the CO and analog device by using standard dial-up test
lines with a transmission test set (for example, Hewlett-Packard 4935A Transmission Test Set).

Longitudinal balance to ground

50 dB
60 to 4000 Hz
With IEEE 455–1976 test

Overload level

3 dB

Mounting keyhole slots

Analog telephone

ATA2

BCM50

BCM50 to ATA2

ATA2 to BCM50

10 dB Max

Cable loss

Central
Office