Preparing the system for maintenance, Removing the power supply, Connect the new power supply – Nortel Networks BCM50 User Manual
Page 172: To remove the power supply
172
Chapter 20 Replacing a power supply
NN40020-302
Preparing the system for maintenance
In most cases, if the power supply for the main unit is faulty, the system is already shut down. If
this is the case, proceed to
on page 172. If you replace the expansion
unit power supply, or if the system is still operating, perform the procedure
Removing the power supply
Before you disconnect the power supply, read the warnings about connecting network lines in
To remove the power supply
1
Remove the telephony and data networking lines from the BCM50 units. These lines include:
•
the RJ-21 telephony connector on the main unit
•
the ADSL line in the WAN port on a BCM50a main unit
•
any analog telephone lines in the media bay modules (MBM) in the expansion units
•
any digital telephone lines in the MBMs in the expansion units
2
Rotate the power supply retention clip to free the power supply cord.
3
Remove the power supply cord from the BCM50 unit.
4
Remove the power supply cord from the AC wall outlet.
If your system has a UPS, remove the power supply cord from the UPS socket.
5
Remove the power supply from the table, rack-mount shelf, or wall-mount bracket.
6
Connect the new power supply
Before you connect the power supply, read the warnings about connecting network lines in
Warning: Leakage currents
You must disconnect the telephony and data networking cables from the system before
disconnecting the power cord from a grounded outlet.