7-8 Troubleshooting

On-screen error message

Recommended action

0B83 BMC IBF or OBF check

failed

1. Take one of the following measures to reboot (reset) the

modular server.
* Issue an OS command.
* Press Ctrl + Alt + Del.
* Issue a command from Web browser of EXPRESSSCOPE

Engine or NEC ESMPRO Manager.

2. Take one of the following measures to power off the modular

server and then on.
* Power off the modular server from OS, then press the

POWER/SLEEP switch to power on.

* Press the POWER/SLEEP switch to power off the modular

server, then press it again to power on.

* Issue a command from Web browser of EXPRESSSCOPE

Engine or NEC ESMPRO Manager.

3. Power off the modular server by issuing an OS command or

press the POWER/SLEEP switch. Take the modular server
out of the Module Enclosure, and install it again. Then, press
the POWER/SLEEP switch to turn on the modular server.

4. If the same error persists, contact your service representative.

0B8A BMC SEL area full

1. Run BIOS SETUP, select [Server] - [Event Log Configuration]

- [Clear All Error Logs] to clear the IPMI system event logs.

2. If the same error persists, contact your service representative.
Note: You can make a backup copy of IPMI system event logs

through the Off-line Maintenance Utility before clearing the
IPMI system event logs on BIOS SETUP.

0B8B BMC progress check

timeout

0B8D Could not redirect the

console - BMC Busy -

0B8E Could not redirect the

console - BMC Error -

0B8F Could not redirect the

console - BMC Parameter
Error -

1. Take one of the following measures to reboot (reset) the

modular server.
* Issue an OS command.
* Press Ctrl + Alt + Del.
* Issue a command from Web browser of EXPRESSSCOPE

Engine or NEC ESMPRO Manager.

2. Take one of the following measures to power off the modular

server and then on.
* Power off the modular server from OS, then press the

POWER/SLEEP switch to power on.

* Press the POWER/SLEEP switch to power off the modular

server, then press it again to power on.

* Issue a command from Web browser of EXPRESSSCOPE

Engine or NEC ESMPRO Manager.

3. Power off the modular server by issuing an OS command or

press the POWER/SLEEP switch. Take the modular server
out of the Module Enclosure, and install it again. Then, press
the POWER/SLEEP switch to turn on the modular server.

4. If the same error persists, contact your service representative.