beautypg.com

NEC EXPRESS5800/100 SERIES N8100-1635F User Manual

Page 70

background image

4-18 Configuring Your Modular Server

Option

Parameter

Description

Your Setting

Thermal Sensor

Disabled
[Enabled]

Specify whether the temperature
sensor monitoring feature is
enabled or disabled. If a thermal
error is detected with this item
being set to "Enabled", the system
stops at the end of POST.

BMC IRQ

Disabled
[IRQ 11]

Specify whether to assign IRQ for
BMC (Baseboard Management
Controller).

Post Error Pause

Disabled
[Enabled]

Specify whether POST is aborted
once at the end of POST if an error
occurs during the execution of
POST.

AC-LINK

Shamrock-G
Stay Off
[Last State]
Power On

Specify the AC-LINK feature.
Shows the system status when the
AC power is supplied again to the
modular server. See the table
below.

Power ON Delay
Time

Default [t1] (s)
[t1-255] (s)

Specify the power-on delay time
between 1 and 255 seconds. This
option is available only when
"Power On" or "Last State" is
specified for AC LINK.

Platform Event
Filtering

Disabled
[Enabled]

Specify whether the Platform
Event Filtering feature of the
Baseboard Management
Controller (BMC) is enabled or
disabled.

[ ]: Factory-set

The table below shows the operation when the AC power to the modular server is turn off once and
then on again, depending on the setting of "AC-LINK".

Setting of AC-LINK

System status before AC power off

Stay Off

Last State

Power On

Operating

Off

On

On

Aborting (DC power being off also)

Off

Off

On

Forced shutdown*

Off

Off

On

* Press the POWER/SLEEP switch continuously for four seconds or longer. This forcibly turns off

the power.