Troubleshooting 7-19

On-screen
message

Description

Action

VBAT Alm 02

A voltage alarm (lower
limit) occurred on lithium
battery.

VBAT Alm 09

A voltage alarm (upper
limit) occurred on lithium
battery.

1. Take one of the following measures to power

off the modular server and then on.
* Power off the modular server from OS,

then press the POWER/SLEEP switch to
power on.

* Press the POWER/SLEEP switch to power

off the modular server, then press it again
to power on.

* Issue a command from Web browser of

EXPRESSSCOPE Engine or NEC
ESMPRO Manager.

2. Power off the modular server by issuing an

OS command or press the POWER/SLEEP
switch. Take the modular server out of the
Module Enclosure, and install it again. Then,
press the POWER/SLEEP switch to turn on
the modular server.

3. Check installation status of the lithium

battery mounted on modular server.

4. If the same error persists, contact your

service representative.