beautypg.com

NEC EXPRESS5800/100 SERIES N8100-1635F User Manual

Page 96

background image

7-6 Troubleshooting

On-screen error message

Recommended action

0B70 The error occurred during

temperature sensor
reading

1. Take one of the following measures to reboot (reset) the

modular server.
* Issue an OS command.
* Press Ctrl + Alt + Del.
* Issue a command from Web browser of EXPRESSSCOPE

Engine or NEC ESMPRO Manager.

2. Take one of the following measures to power off the modular

server and then on.
* Power off the modular server from OS, then press the

POWER/SLEEP switch to power on.

* Press the POWER/SLEEP switch to power off the modular

server, then press it again to power on.

* Issue a command from Web browser of EXPRESSSCOPE

Engine or NEC ESMPRO Manager.

3. Power off the modular server by issuing an OS command or

press the POWER/SLEEP switch. Take the modular server
out of the Module Enclosure, and install it again. Then, press
the POWER/SLEEP switch to turn on the modular server.

4. If the same error persists, contact your service representative.

0B71 System Temperature out

of the range

1. Check if fans in Module Enclosure work normally.
2. Refer to the User’s Guide of the Module Enclosure to make

sure that the sufficient number of fans are installed in correct
locations.

3. Check if the fans and modular servers are installed in correct

locations.

4. Check installation status of heat sink of the modular server.
5. Check if the ambient temperature of installation location

satisfies the operation guarantee condition.

6. Take one of the following measures to reboot (reset) the

modular server.
* Issue an OS command.
* Press Ctrl + Alt + Del.
* Issue a command from Web browser of EXPRESSSCOPE

Engine or NEC ESMPRO Manager.

7. Take one of the following measures to power off the modular

server and then on.
* Power off the modular server from OS, then press the

POWER/SLEEP switch to power on.

* Press the POWER/SLEEP switch to power off the modular

server, then press it again to power on.

* Issue a command from Web browser of EXPRESSSCOPE

Engine or NEC ESMPRO Manager.

8. Power off the modular server by issuing an OS command or

press the POWER/SLEEP switch. Take the modular server
out of the Module Enclosure, and install it again. Then, press
the POWER/SLEEP switch to turn on the modular server.

9. If the same error persists, contact your service

representative.