Anti-static measures – NEC EXPRESS5800/100 SERIES N8100-1635F User Manual
Page 137

Upgrading Your Modular Server 8-3
ANTI-STATIC MEASURES
The modular server contains electronic components sensitive to static electricity. Avoid failures
caused by static electricity when installing or removing any optional devices.
Wear a wrist strap (an arm belt or anti-static glove).
Wear a wrist strap on your wrist. If no wrist strap is available, touch an unpainted metal
part of the cabinet before touching a component to discharge static electricity from your
body.
Touch a metal part regularly when working with components to discharge static
electricity.
Select a suitable work space.
– Work with the modular server on the anti-static or concrete floor.
– When you work with the modular server on a carpet where static electricity is likely to
be generated, make sure take anti-static measures beforehand.
Use a work table.
Place the modular server on an anti-static mat to work with it.
Cloth
– Do not wear a wool or synthetic cloth to work with the modular server.
– Wear anti-static shoes to work with the modular server.
– Take off any jewels (a ring, bracelet, or wrist watch) before working with the modular
server.
Handling of components
– Keep any component in an anti-static bag until you actually install it to the modular
server.
– Hold a component by its edge to avoid touching any terminals or parts.
– To store or carry any component, place it in an anti-static bag.