7-26 Troubleshooting

On-screen
message

Description

Action

Proc 1.05v Alm 00

1.05V voltage warning
(lower limit) was detected
on processor.

Proc 1.05v Alm 07

1.05V voltage warning
(upper limit) was detected
on processor.

Proc Core Alm 00

A core voltage warning
(lower limit) was detected
on processor.

Proc Core Alm 07

A core voltage warning
(upper limit) was detected
on processor.

1. Take one of the following measures to power

off the modular server and then on.
* Power off the modular server from OS,

then press the POWER/SLEEP switch to
power on.

* Press the POWER/SLEEP switch to power

off the modular server, then press it again
to power on.

* Issue a command from Web browser of

EXPRESSSCOPE Engine or NEC
ESMPRO Manager.

2. Power off the modular server by issuing an

OS command or press the POWER/SLEEP
switch. Take the modular server out of the
Module Enclosure, and install it again. Then,
press the POWER/SLEEP switch to turn on
the modular server.

3. Check installation status of the heat sink of

the modular server.

4. If the same error persists, contact your

service representative.