Troubleshooting 7-17

When STATUS lamp is lighting in amber:

On-screen
message

Description

Action

Proc Temp Alm 02

A low temperature alarm
is detected in processor.

Proc Temp Alm 09

A high temperature alarm
is detected in processor.

1. Check if fans in Module Enclosure work

normally.

2. Refer to the User’s Guide of the Module

Enclosure to make sure that the sufficient
number of fans are installed in correct
locations.

3. Check if the fans and modular servers are

installed in correct locations.

4. Check installation status of the heat sink of

the modular server.

5. Check if the operating environment satisfies

the required guaranteed temperature.

6. Take one of the following measures to

reboot (reset) the modular server.
* Issue an OS command.
* Press Ctrl + Alt + Del.
* Issue a command from Web browser of

EXPRESSSCOPE Engine or NEC
ESMPRO Manager.

7. Take one of the following measures to power

off the modular server and then on.
* Power off the modular server from OS,

then press the POWER/SLEEP switch to
power on.

* Press the POWER/SLEEP switch to power

off the modular server, then press it again
to power on.

* Issue a command from Web browser of

EXPRESSSCOPE Engine or NEC
ESMPRO Manager.

8. Power off the modular server by issuing an

OS command or press the POWER/SLEEP
switch. Take the modular server out of the
Module Enclosure, and install it again. Then,
press the POWER/SLEEP switch to turn on
the modular server.

9. If the same error persists, contact your