Troubleshooting 7-15

Messages displayed on lower line

When STATUS lamp is off:

On-screen
message

Description

Action

SMI Timeout

A timeout error occurred
during system
management interrupt.

1. Take one of the following measures to

reboot (reset) the modular server.
* Issue an OS command.
* Press Ctrl + Alt + Del.
* Issue a command from Web browser of

EXPRESSSCOPE Engine or NEC
ESMPRO Manager.

2. Take one of the following measures to power

off the modular server and then on.
* Power off the modular server from OS,

then press the POWER/SLEEP switch to
power on.

* Press the POWER/SLEEP switch to power

off the modular server, then press it again
to power on.

* Issue a command from Web browser of

EXPRESSSCOPE Engine or NEC
ESMPRO Manager.

3. Power off the modular server by issuing a

command from OS or pressing the
POWER/SLEEP switch. Remove the
modular server from Module Enclosure, then
install it again. Then press the
POWER/SLEEP switch to power on the
modular server.

4. If the same error persists, contact your

service representative.

DUMP Request!

DUMP switch was
pressed.

Wait until OS dump process completes.
1. If the dump process is not complete, take

one of the following steps.
* Issue a command from OS.
* Press Ctrl + Alt + Del.
* Issue a command from Web browser of

EXPRESSSCOPE Engine or NEC
ESMPRO Manager.

2. Take one of the following measures to power

off the modular server and then on.
* Power off the modular server from OS,

then press the POWER/SLEEP switch to
power on.

* Press the POWER/SLEEP switch to power

off the modular server, then press it again
to power on.

* Issue a command from Web browser of

EXPRESSSCOPE Engine or NEC
ESMPRO Manager.

3. If the same error persists, contact your