Troubleshooting 7-5

On-screen error message

Recommended action

0250

System battery is dead -
Replace and run SETUP

1. Take one of the following measures to power off the modular

server and then on.
* Power off the modular server from OS, then press the

POWER/SLEEP switch to power on.

* Press the POWER/SLEEP switch to power off the modular

server, then press it again to power on.

* Issue a command from Web browser of EXPRESSSCOPE

Engine or NEC ESMPRO Manager.

2. Power off the modular server by issuing an OS command or

press the POWER/SLEEP switch. Take the modular server
out of the Module Enclosure, and install it again. Then, press
the POWER/SLEEP switch to turn on the modular server.

3. Check installation status of the lithium battery on modular

server.

4. If the same error persists, contact your service representative.
Note: Restart the modular server, run BIOS SETUP, and provide

settings for date, time, and others.

0251

System CMOS checksum
bad - Default configuration
used

The default configuration of BIOS SETUP is used.
1. Run the BIOS SETUP utility to correct the setting.
2. If the same error persists, contact your service representative.

0252

Password checksum bad -
Passwords cleared

The password has been cleared.
1. Run the BIOS SETUP utility to correct the setting.
2. If the same error persists, contact your service representative.

0260

System timer error

0270

Real timer error

1. Take one of the following measures to power off the modular

server and then on.
* Power off the modular server from OS, then press the

POWER/SLEEP switch to power on.

* Press the POWER/SLEEP switch to power off the modular

server, then press it again to power on.

* Issue a command from Web browser of EXPRESSSCOPE

Engine or NEC ESMPRO Manager.

2. If the same error persists, contact your service representative.

0271

Check date and time
setting

1. Run the BIOS SETUP utility to set the current date and time.
2. If the same error persists, contact your service representative.

02D0

1. Take one of the following measures to reboot (reset) the

modular server.
* Issue an OS command.
* Press Ctrl + Alt + Del.
* Issue a command from Web browser of EXPRESSSCOPE

Engine or NEC ESMPRO Manager.

2. Take one of the following measures to power off the modular

server and then on.
* Power off the modular server from OS, then press the

POWER/SLEEP switch to power on.

* Press the POWER/SLEEP switch to power off the modular

server, then press it again to power on.

* Issue a command from Web browser of EXPRESSSCOPE

Engine or NEC ESMPRO Manager.

3. If the same error persists, contact your service representative.